spacer
Listing 4511508 Listing 4511508
Listing 4511508 Listing 4511508

For Sale BARD Labsystem pro EP Lab/X-Ray Room

  • Condition : Refurbished
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 11, 2024
  • Listing # : 4511508
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4511508

  • Condition: Refurbished
  • Brand: BARD
  • Type: EP Lab/X-Ray Room
  • Model: Labsystem pro
Bard LabPro
Bard Lab Pro computer LS8900 workstation windows 7 with keyboard
One Bard Lab Pro EP amplifier with catheter input Cable and accessories capable of 160 channels
Includes two 80 channel catheter cable
Two 20” display monitors
HP M401 Laser printer

The LABSYSTEM PRO EP Recording System is a computer and software driven data acquisition and analysis tool designed to facilitate the gathering, display, analysis by a physician, pace mapping and storage of intra cardiac electrophysiological data.


The CLEARSIGN Amplifier is intended to amplify and condition electrocardiographic signals of biologic origin and pressure transducer input, transmitting this information to a host computer (the LABSYSTEM PRO EP Recording System) that can record and display the information up to 80
Channels , includes EKG and two catheter input cables

Includes Micropace III
Micropace EP320 2- Channel Stimulator

The EPS320 software allows interactive programming of all aspects of the pacing stimulus: the current amplitude, pulse width, channel, and all stimulus parameters including drive train number, timing and up to 6 extra-stimuli. The stimulator has an intuitive user interface, with all commonly used stimulus and pacing protocol parameters located on fixed menus on the one screen instantly adjustable via hotkeys including during actual pacing. All standard EP stimulation protocols are available pre-programmed but may be reconfigured and automated according to user requirements.

The Stimulus Generator Unit is mains-powered via a DC power supply and has an internal trickle-charged backup battery in case of power failure. Its outputs are defibrillator and RF energy protected and it features external ECG input ports as well as catheter-tip ECG sensing for triggering of pacing events and one trigger output channel for synchronization with other equipment. The system is powered from the mains via a medical grade isolation transformer.

The two stimulation channels are independent isolated constant current pulse generators capable of generating 0.5 to 10ms pulses at 0.1 to 25mA with a maximum output voltage of 27V. The stimulus output may be used to stimulate the human heart during electrophysiological studies via any third party legally marketed transvenous intracardiac pacing catheters directly or via any third party legally marketed EP recording equipment, e.g. Axiom Sensis.

The Micropace Stimulus Multiplexer Box generates 4 stimulus output channels from the EPS320’s existing 2 physical stimulus generators by automatic simultaneous reprogramming of stimulus current and physical switching. Simultaneous pacing is limited to Channel 1+2 or Channel 3+4, but not from all four outputs.

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
DB Medical Electronics
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: