HOLOGIC Discovery Ci Bone Densitometer

Not Rated Rate this modal

Clinical Applications

• Express BMD 10 Second Spine and Hip acquisition
• Express Exam Productivity Tools
• Better than 1.0 % in vivo precision
• L1-L4 Standard Spine Analysis
• Five Region Proximal Femur Analysis (Total Femur, Femoral Neck,
Inter-Trochanteric,Trochanteric, Wards Triangle)
• AcuView automated Dual Femur
• Instant Vertebral Assessment High Definition (IVA HD) with Image Pro
• 15 second single energy acquisition with decubitus or supine patient
positioning
• 1.8 Line Pair per mm Resolution
• Visual, Quantitative and Semi-quantitative analysis of vertebral bodies:
• MXApro, computer-aided fracture assessment tool
• Quantitative Morphometry with 6 point vertebral height measurements
• Forearm analysis with automated analysis of Ultra Distal, 33% Shaft,
Mid-Shaft and Total ROI for Ulna, Radius and Global measurements
• Tech Tips Onscreen help graphically displays proper patient positioning
• Automatic Low BMD Spine and Hip Analysis
• Scoliotic Spine Analysis
• Pediatric Spine, Hip, and Whole Body (W and A models only) Analysis
• Infant Spine analysis down to age zero
• ISCD Compliant Standardized BMD Reporting
• Single/Dual Energy Image Display
• Context Sensitive Help Software
• Serial Scan Comparison
• Software and Hardware upgrades available to protect from obsolescence

Warranty/Training

Service and Support
• Toll Free Customer Support Hotline for Applications Questions
• 7:00a.m.-8:00p.m. EST Access Monday through Friday
• Hologic Discovery Online Marketers Toolbox
• Osteoporosis Reference Library

Applications Training
• Two days (12 hours) of comprehensive Applications training by a certified Radiologic Technologist.
• 12 ECE Credits Awarded for Completion of Course Material.

Quality Assurance
• Automated daily procedure
• Multiple system checks with automatic pass/fail results
• Anthropomorphic Spine Phantom for Daily Quality Control assures long term
stability
• Automatic trending graph of QA variables
• Optional print of QA graph

Radiation Dose
• Skin entrance dose for a typical AP Spine or Femur Scan is 0.04mGy
• Skin entrance dose for typical AP or Lateral Instant Vertebral Assessment High Definition image is 0.025Gy
• Scatter dose less than 10mGy/h at 1 meter

See a missing Specification? Want to make a correction? Add it now
Size:
142 x 105 x 193 (scanner table)
Weight:
650 pounds
Calibration:
Internal Reference System for Pixel by Pixel Data Calibration (No daily calibration required)
Computer Hardware:
Intel Pentium based PC with Dual Core 2.7 GHz • 2 GB RAM • 160 GB hard drive, • DVD RAM Drive • High Resolution 17" Flat Panel Monitor • Windows XPâ software platform • QDR for Windows XPâ Professional operating system • Network Ready
Power Supply Voltage:
Energy switching technique using 140/100kV Peak Energies
Reference Data:
(n>8000 acquired on Hologic equipment) • Default NHANES III standardized database (Established on Hologic equipment) • Age, Sex and Ethnic matched reference data • The Bone and Mineral Density in Childhood Study (BMDCS) Reference Database, Caucasian, sex and age matched
Scanner table:
Controls on scan table for User Convenience, Motorized Table and Rotating C-arm (A/SL models only)
Scanning Method:
Cross Hair Style Laser for Patient Positioning
Table Dimensions:
Compact Design fits in 2.3m x 3.0 room (2.6m x 3.3m with total body)
X-ray characteristics:
Oil Cooled High Capacity X-ray Tube

Share your opinion or experience with this equipment Review this model