For Sale Agilent 1260 Infinity II Bio-Inert LC System
(Needs Bio-Inert Quaternary Pump G5654A and Bio-Inert Multisampler G5668A to be complete system)
• Fully Functional
• Serviced & in Stock
• Current Model
• Good cosmetic condition
• Technical sales consultation available
• WARRANTY
________________________________________
Here is what you will receive:
• Agilent 1260 Infinity II Multiple Wavelength Detector (MWD) p/n: G7165A with bio-inert standard flow cell, with RFID tag, 10 mm, 13 uL, 120 bar p/n: G5615-60022
• Agilent 1260 Infinity II Multicolumn Thermostat p/n: G7116A
• Agilent 1290 Infinity Thermostat module for Fraction Collector p/n: G1330B
• Agilent 1260 Infinity II Bio-inert Fraction Collector p/n: G5664B
• 1x Fraction Collector Tray for 215 test tubes, 12mm OD, max tube height: 48mm p/n: G1364-84536
• 1x 4-Plates tray, cooled p/n: G1364-60621
• Solvent bottle tray
• Power and communication cables
Please Note: The computer and or OpenLab CD software and proper licenses for final configuration should be purchased separately from Waters. They are not included.
(Needs Bio-Inert Quaternary Pump G5654A and Bio-Inert Multisampler G5668A to be complete system)
Agilent 1260 Infinity ll LC System Configuration:
Agilent 1260 Infinity II Multiple Wavelength Detector:
• Detection type: 1024-element photodiode array
• Number of signals: 8
• Maximum data rate: 120 Hz
• Short-term signal noise (ASTM): < ± 0.7·10-5 AU at 254 nm and 750 nm
• Drift: < 0.9·10-3 AU/h at 254 nm
• Linear absorbance range: > 2 AU (5 %) at 265 nm
• Wavelength range: 190 – 950 nm
• Wavelength accuracy: ± 1 nm,
• Wavelength bunching: 1 – 400 nm
• Slit width: 1, 2, 4 , 8, 16 nm
• Diode width: < 1 nm
• Time programmable: wavelength, polarity, peak width, lamp bandwidth, auto balance, wavelength range, threshold, spectra storage mode
• Flow cell: standard bio-inert: 13 uL volume, 10 mm cell path length and 120 bar pressure maximum
Agilent 1260 Infinity II Multicolumn Thermostat:
• Operating principle: thermostatted column compartment with dual, independent Peltier-element. Solvent pre-heating and still-air operation for reduction of chromatographic band-broadening under UGPC conditions.
• Temperature range: 10 DegC below ambient (minimum 4 DegC) to 85 DegC
• Temperature range increment: settable in steps of 0.1 DegC
• Temperature stability ±0.1 DegC
• Temperature accuracy ±0.5 DegC (with calibration at 40 DegC)
• Temperature precision 0.05 DegC
• Independent temperature zones: 2 in single device
• Column capacity: 4 columns of up to 300 mm length plus InfinityLab Quick Connect fittings or pre-column.
• Heat-up/cool-down time: 5 min from ambient to 40 DegC; 10 min from 40 DegC to 20 DegC; 25 min from 25 DegC to 85 DegC
• Weight: 12.5 kg (27.6 lbs)
• Dimensions: (H×W×D): 16 x 43.5 x 43.6 cm. (6.3 x 17.1 x 17.2 in.)
• Power requirements: 100 – 240 V~, ± 10 % 50/60 Hz, ± 5 %, 150 VA, 150 W
Agilent 1290 Infinity Thermostat Module:
• Temperature range: settable from 4DegC to 40DegC in 1DegC increments
• Temperature accuracy at ambient temperatures < 25DegC and humidity <50%: 3 DegC to 8 DegC at a setpoint of 4 DegC
• Temperature accuracy at ambient temperatures <30 DegC and humidity <60%: 3 DegC to 9 DegC at a setpoint of 4 DegC
Agilent 1260 Infinity II Bio-inert Fraction Collector:
• Plates/trays: 4 x well-plates full tray (only one type of well-plates can be used at a time in one tray); full tray with 215 test tubes (12 mm OD, max. height 48 mm, ~8 mL / tube)
• Delay Volume: fraction collector inlet to diverter valve: ~50 ul; diverter valve: ~15 ul; diverter valve to needle: ~10 ul; needle: ~4 ul
• Maximum system flow: 10 mL/min
• Maximum collection volume: up to 20 mL
• Maximum capacity: 3 fraction collectors in parallel plus one recovery fraction collector
• Cooling: thermostat module p/n: G1330B included, performance depending on ambient conditions and the volume of collected fractions
• Trigger modes: time slices, peak, timetable
• Trigger Source: G7165A, 1260 Infinity II MWD
• Operating Modes: discrete fractions, continuous flow, needle into location, droplet setup mode
• Maximum time to move between neighboring vessels: movement in x-direction: < 0.15 s.; movement in y-direction: < 0.3 s
• Diverter valve: 3/2 valve, switching time: < 100 ms
• Maximum pressure: 6 bar at the diverter valve during switching
Customization/Options:
• Other detectors and flow cell options might be available. Please inquire with our sales team.
Testing performed by our in-house service team:
Agilent 1260 Infinity II Multiple Wavelength Detector:
• We performed the initialization test.
• We conducted the software communication test.
• We conducted the cell test.
• We performed the dark current test to verify baseline stability.
• We conducted the filter test to check optical filter performance.
• We carried out the holmium oxide test to verify wavelength accuracy.
• We performed the intensity test to ensure appropriate signal strength.
• We conducted the slit test to check for proper light dispersion.
• We verified the wavelength accuracy with the wavelength verification test.
• We performed the noise and drift test to ensure signal stability over time.
Agilent 1260 Infinity II Multicolumn Thermostat:
• We ensure the successful initialization of the system.
• We verify the communication functionality with the control software.
• We assess the efficiency and reliability of the cooling and heating functionality.
Agilent 1290 Infinity Thermostat Module:
• We performed the initialization test to verify proper startup.
• We conducted the software communication test to verify seamless integration with the system.
• We carried out the cooling test to verify efficient temperature regulation.
Agilent 1260 Infinity II Bio-inert Fraction Collector:
• We performed the initialization test.
• We verified seamless communication with the software.
• We verified the sample rack detection to ensure correct identification.
• We tested the arm movement to confirm precise positioning.
• We checked the collection of the sample to validate accurate fraction collection.
Instrument Overview:
• The Agilent 1260 Infinity II Bio-Inert LC System is designed for high-performance liquid chromatography (HPLC).
• It features biocompatible materials to prevent sample contamination and ensure accurate results.
• This LC system offers high resolution and sensitivity for reliable analysis.
• We recommend a quaternary pump and multisampler for flexibility and efficiency.
• The Agilent 1260 Infinity II Bio-Inert LC System supports a wide range of flow rates and pressures.
Instrument Application:
• Analysis of biomolecules such as proteins, peptides, and nucleic acids.
• Separation and quantification of monoclonal antibodies and biosimilars.
• Characterization of complex biological samples in pharmaceutical research.
• Quality control in the production of biotherapeutics.
• Analysis of metabolites and other small molecules in clinical research.
• Purity testing of biocompatible materials and drug formulations.
The Key Features:
• The Biocompatible flow path prevents sample contamination and degradation.
• The Recommended high-performance quaternary pump supports a wide range of solvents and flow rates.
• Temperature-controlled column compartment for consistent separation conditions.
• Compatible with a wide range of detectors for versatile application needs.
Why do so many customers choose to order from us?
Our Advantage
• We have experience servicing and repairing these instruments.
• This instrument goes through all the described service steps before shipping. see questions section below
• We offer detailed photos and videos of the instruments you buy.
• We are an approved pre-owned equipment vendor to many large US, Canadian, and EU Universities.
• We are an approved pre-owned equipment vendor to many Fortune 500 US and International Biopharma companies.
• Technical sales consultation available
• Remote installation and instrument operation training may be available.
• On-site installation may be available in the Boston Area (New England area)
• US or International shipping is no problem (see the shipping tab on how we pack and feel at ease)
Our Guarantee
• Warranty
• An extended warranty may be available
• You get after-sales technical support
• Customer references are available
• The instrument will be fully functional!
• Smooth process from the initial quote to order fulfillment
________________________________________
This will ship via freight. Please contact us with your zip code to obtain a shipping quote.
PLEASE NOTE THAT THE QUESTIONS BELOW ARE ANSWERED IN MORE THOROUGH DETAIL ON OUR WEBSITE
Q: Can I view this instrument in person at your facility or do a live Zoom demo before it is shipped to me?
A: We can accommodate both in-person or Zoom demos.
Q: What about the warranty?
A: The instrument comes fully warranted for both parts and labor.
Q: Do you offer installation, service, etc?
A: We offer remote installation and training packages to familiarize you with this instrument.
Q: What should I watch out for when buying a used/pre-owned instrument from another lab?
A: Ensure that the instrument is in good working condition with no damage or wear that could affect its performance. Ask for details about testing steps performed, video demo, and test screenshots.
Q: Do you have more than one of these instruments on hand?
A: We generally carry multiple instruments on hand, along with a variety of spare parts.
Q: This procurement is for a University or College. Are purchase orders with NET terms accepted?
A: We accept purchase orders from all major US and Canadian universities.
Q: How fast will you ship?
A: We can ship within a few days to two weeks. Shipping time depends on the current demand for our instruments. Members of our sales team will be able to offer current delivery estimates.
Q: Will my instrument be insured during shipping?
A: Absolutely! We insure all our shipments as long as we are the shipper. If a customer ships on their account, they handle insurance.
Q: How do you pack? Have you previously packed and shipped the fragile laboratory instruments?
A: We have extensive experience shipping high-end and complex laboratory instruments in the US and Internationally.
Q: Do you ship Internationally?
A: Yes! We have shipped to multiple continents and over 30 countries.
Q: How much will I save buying it pre-owned, and is it worth it?
A: When compared to buying a new instrument, you will save 60% or more and have plenty of funds left over for an additional instrument or two.
TO VIEW ADDITIONAL PHOTOS, VIDEOS AND VERY DETAILED INFORMATION SUCH AS TEST STEPS PERFORMED, CONFIGURATION, ETC., PLEASE VISIT OUR WEB SITE. TO GET THERE PLEASE CLICK ON “WEBSTORE”; TO YOUR RIGHT AND YOU WILL SEE LINK TO OUR SITE IN THE MIDDLE OF THE SCREEN. THEN USE LAST 5 DIGITS OF MPN NUMBER IN THE SEARCH FIELD TO LOCATE YOUR ITEM.
DO NOT HESITATE TO CALL US OR EMAIL US WITH ANY QUESTIONS YOU MIGHT HAVE.
ALL OF OUR ITEMS ARE AVAILABLE FOR INSPECTION AT OUR FACILITY.
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.