Over 850 Total Lots Up For Auction at One Location - NJ Cleansweep 06/13

spacer
Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265
Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265 Listing 4308265

For Sale POCVODA PV-2000DV ICU/CCU

  • Asking Price :$480.00 USD [convert]
  • Condition : New
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 27, 2024
  • Listing # : 4308265
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4308265

  • Condition: New
  • Brand: POCVODA
  • Type: ICU/CCU
  • Model: PV-2000DV
  • MPN: PV-2000DV
  • Warranty: 12 MONTHS
Product Function
1.13Type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titration table
2. Efficient resistance to interference of defibrillator and electrosurgical cautery
3. SPO2 can testing for 0.1% Weak
4. RA-LL impedance Respiration
5. Trend Coexist Display
6. OxyCRG DyNamic View Display
8. Networking capacity
9. Options of printing, IBP, VGA and EtCO2, touch screen.
10. UP to 4 hours working capacity of built_in rechargeable battery.
11, 12.1"high resolution color TFT LCD display.
12, Large volume of tabular and graphic trends information storage and easy to recall.
13, Anti-ESU, anti- defibrillator
14, 6 Standard parameters:ECG,RESP,NIBP,SPO2,1_TEMP,PR/HR.
15, Capture dynamic waveforms.

Product Specification
ECG
Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection: I, II, III, avR, avL, avF, V,
Waveform: 2 ch
Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
Lead selection: I, II, III,
Waveform: 1 ch
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, auto
HR and Alarm
Range
Adult: 15 ~ 300 bpm
Neo/Ped: 15 ~ 350 bpm
Accuracy : ± 1% or ± 1bpm,which great
Resolution: 1 bpm
Sensitivity: > 200 (uV P-P)
Differential Input Impedance: > 5 MΩ
CMRR
Monitor: > 105 dB
Operation: > 105 dB
Diagnosis: > 85 dB
Electrode offset potential: 300mV
Leakage Current: < 10 uA
Baseline Recovery: < 3 S After Defi.
ECG Signal Range: 8 m V ( Vp-p )
Bandwidth
Surgery: 1 ~ 15 Hz
Monitor: 0.5 ~ 35 Hz
Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p), Accuracy:5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm: Available
Review: Available
RESPARATION
Method: Impedance between R-F(RA-LL)
Differential Input Impedance: >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5 KΩ
Bandwidth: 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult: 0 ~ 120 rpm
Neo/Ped: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy : 2 rpm
Apean Alarm: 10 ~ 40 S
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS: 40 ~ 270 mmHg
DIA: 10 ~ 215 mmHg
MEAN: 20 ~ 235 mmHg
Pediatric Mode
SYS: 40 ~ 200 mmHg
DIA: 10 ~ 150 mmHg
MEAN:20 ~ 165 mmHg
Neonatal Mode
SYS: 40 ~ 135 mmHg
DIA:10 ~ 100 mmHg
MEAN:20 ~ 110 mmHg
Resolution Pressure:1mmHg
Accuracy Pressure Maximum Mean error: 5mmHg
Maximum Standard deviation: 8mmHg
Overpressure Protection
Adult Mode: 2973 mmHg
Pediatric Mode: 2403 mmHg
Neonatal Mode: 1473 mmHg
SpO2
Measuring Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy : 70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: 10 Sec.
Pulse Rate
Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy : 2bpm
TEMPERATURE
Channel: 1
Measuring and Alarm Range: 0 ~ 50 C
Resolution: 0.1C
Accuracy : 0.1C
Actualization interval: about 1 Sec.
Average Time Constant:<10 Sec.
IBP(Optional)
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART: 0 ~ 300 mmHg
PA: -6 ~ 120 mmHg
CVP/RAP/LAP/ICP: -10 ~ 40 mmHg
P1/P2: -10 ~ 300 mmHg
Press Sensor
Sensitivity: 5 uV/V/mmHg
Impedance: 300-3000Ω
Resolution: 1 mmHg
Accuracy : 2% or 1mmHg, which great
Actualization interval: about 1 Sec.