Over 150 Total Lots Up For Auction at One Location - UT 04/29

spacer
STOCKERT 3T Hypmia Unit STOCKERT 3T Hypmia Unit STOCKERT 3T Hypmia Unit STOCKERT 3T Hypmia Unit
STOCKERT 3T Hypmia Unit STOCKERT 3T Hypmia Unit STOCKERT 3T Hypmia Unit STOCKERT 3T Hypmia Unit

For Sale STOCKERT 3T Hypothermia Unit

  • Condition : Used - Good
  • Qty. Available : 2
  • In Stock : Yes
  • Date : April 21, 2025
  • Listing # : 4548983
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4548983

  • Condition: Used - Good
  • Brand: STOCKERT
  • Type: Hypothermia Unit
  • Model: 3T
HEATER COOLER STOCKERT 3T YOM 2018
CONDITION LIKE NEW , COMES WITH ALL ACCESSORIES
READY TO USE ON THE PATIENT
Short pre-cooling time
2 Small volume tanks for warming and Cooling
Independent safety system to prevent the water temperature from reach critical temperatures
Two-chamber pumps to minimize the pressure inside the heating chamber
The Suction of the pumps allows for a smooth emptying of the heating chamber and the tubing
3T Heart-Cooler Specifications
Dimensions
Height: 33.2 in (97.5 cm)
Width: 19.8 in (50 cm)
Depth: 26.8 in (68 cm)
Weight: 228.5 lbs (102 kg)
Operating Conditions
Operating Temperature: 10 °C through 30 °C Note: Cooling performance might be reduced at operating temperatures greater than 25 °C.
Relative Humidity: 30% through 75%
Operating altitude (atmospheric pressure): 0 ... 2,000 m (700hPa ... 1,060 hPa)
Storage Conditions
Storage Temperature: -10 °C through 60 °C
Relative Humidity: 0% through 80%
Atmospheric Pressure: 500 hPa through 1,060 hPa (7.3 psi through 15.4 psi)
Transport Conditions
Transport Temperature: -10 °C through 60 °C
Relative Humidity: 0% through 85%
Atmospheric Pressure: 500 hPa through 1,060 hPa (7.3 psi through 15.4 psi)
Volume and Flow
Minimum level patient tank 4.5 L (11.6 L total tank volume)
Maximum level patient tank 6.5 L (13.8 L total tank volume)
Water flow patient circuits
13.0 - 16.4 liters per minute (circuit outlet)
10.8 – 12.6 liters per minute (5 m + 5 m circuit)
Water flow cardioplegia circuit
7.5 – 9.8 liters per minute (circuit outlet)
7.4 – 8.7 liters per minute (5 m + 5 m circuit)
Water pressure in patient circuits 0.63 – 0.79 bar
Water pressure in cardioplegia circuits 0.65 – 0.72 bar
Power
Power Needed, VAC: 110/220-240

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
AL RAS MEDICAL DEVICES TR LLC
Citi Capital Groupspacer
Send the Seller a message: