The Siemens Dade Dimension ARx may be purchased in 1 of 2 ways listed below.
1.) Siemens Dade Dimension ARx complete, working when shut down, cleaned, and crated.
2.) Siemens Dade Dimension ARx refurbished by a factory trained service engineer, with completed manufacture specific preventive maintenance documentation, and crated.
***Don't forget to ask for your multiple unit, reagent, and consumable discount. ***
The Siemens Dade Dimension ARx
The Siemens Dade Dimension ARX clinical chemistry system is a discrete, random-access, microprocessor-controlled, integrated instrument/chemistry system that measures a variety of analytes, including enzyme activities, in body fluids.containers, some of which require adapters. Multiple tests can be requested from a single sample. The sample containers are placed into segments, which the operator loads into the sample area of the instrument. The operator also places Flex reagent cartridges into the autoloader, which moves them into the reagent tray. When processing begins, several events take place. The IMT probe performs a level sense (on sample tube) or level detect (on sample cups and SSCs) to determine if adequate volume is present for the requested tests. If the reagent to be used requires hydration, the Flex cartridge is moved into a position where R2 reagent probe performs the necessary preparation by ultrasonically fragmenting tablets and aspirating and dispensing liquids as required. The cuvette area manufactures one cuvette every 7.2 seconds. The reagent tray moves the appropriate reagent cartridge into position for access by the R1 reagent arm. The sample probe aspirates sample from the container and dispenses it into the cuvette. The R1 probe aspirates reagent from the Flex cartridge and dispenses it into the cuvette. Urine tests are automatically diluted. The IMT probe aspirates sample from the container and dispenses it with water into the aliquot wheel. The sample probe aspirates sample from the aliquot wheel and dispenses it to the cuvette. To prevent carryover, the Siemens Dade Dimension ASX’s probes are rinsed in their respective drains after each aspiration and dispensing action. If a test is programmed for automatic dilution when it exceeds linearity, the system reruns the test with the sample probe dispensing water and sample into the cuvette. The cuvette is warmed in the thermal chamber where the chemical reaction takes place. The photometer measures the wavelengths of the cuvette contents and the system translates the absorbance into the concentration reported on the results printout. When processing of all samples in a segment are complete, the operator can remove the segment and load a new one without interrupting processing of other segments/samples. Used cuvettes move into the waste container.
Siemens Dade Dimension ARx IMT System:
The IMT system processes electrolyte tests. The IMT probe aspirates sample from the container and dispenses as a 1:10 dilution into the IMT port. The diluted sample travels through tubing from the port to the QuikLYTE multisensor tower. At the tower, the multisensor measures Na, K, and Cl. The IMT pump then moves the sample to the TCO2 mixer where it is mixed with TCO2 release agent, then measured by the TCO2 electrode.
Siemens Dade Dimension ARx System Features:
• The Siemens Dade Dimension ARx performs tests in random order.
• The Siemens Dade Dimension ARx uses the Dade Behring Inc. low-cost-per-test Flex reagent cartridge and onboard cuvette manufacturing system.
• The Siemens Dade Dimension ARx uses the Dade Behring Inc. exclusive QuikLYTE Integrated Multisensor for electrolyte testing.
• The Siemens Dade Dimension ARx performs up to 500 photometric chemistry tests and 288 electrolyte tests per hour on serum, plasma, urine, or cerebrospinal fluid samples.
• The Siemens Dade Dimension ARx performs automatic reflex testing.
• The Siemens Dade Dimension ARx performs automatic panic run.
• The Siemens Dade Dimension ARx uses various sizes and styles of primary sample tubes.
• The Siemens Dade Dimension ARx uses 1.5-mL sample cups
• The Siemens Dade Dimension ARx uses 1-mL SSC containers on top of bar coded tubes.
• The Siemens Dade Dimension ARx holds up to 44 Flex reagent cartridges in a non-CFC refrigeration system.
• The Siemens Dade Dimension ARx performs automatic reagent preparation.
• The Siemens Dade Dimension ARx has an easy-to-use computer.
• The Siemens Dade Dimension ARx has ten user-programmable panel keys.
• The Siemens Dade Dimension ARx has the ability to link with other Dade Behring Inc. analyzers (with or without bar code generation capability) or with a Laboratory Information System (LIS).
• The Siemens Dade Dimension ARx has the ability to produce calculated results.
• The Siemens Dade Dimension ARx has automatic rerun capability.
• The Siemens Dade Dimension ARx has automatic dilution for over range samples.
• The Siemens Dade Dimension ARx performs an automatic dilution on urine samples.
• The Siemens Dade Dimension ARx has the capability to process user-defined methods.
• The Siemens Dade Dimension ARx has the ability to automatically remove reagent cartridges when these cartridges are empty or their on-board life has expired.
• The Siemens Dade Dimension ARx offers a LCD flat panel display.
You can use the following types of sample containers on the Siemens Dade Dimension ARx clinical chemistry system:
• Sample cups with lids.
• Small Sample Containers (SSC) supplied by Dade Behring Inc.
• Un-stoppered primary 5-mL, 7-mL, and 10-mL primary sample tubes.
• Pediatric tubes of various sizes and capacities.
The Siemens Dade Dimension ARx Instrument Specifications
Instrument Weight and Dimensions:
Weight: 673 lb (305 kg)
Dimensions: 50in (127cm) Wide x 45in (114cm) High (without monitor) x 33in (81cm) Deep
Additional Instrument Clearances (Minimum):
• Monitor left side clearance— 16.5in. (42cm)
• Cooling fan clearance on right side— 3in. (8cm)
• Ventilation clearance in back— 6in. (15cm)
• Doorway opening for installation— 33in. (84cm)
Room Environment Operating Temperature:
Room temperature must be 65–85°F (18– 29°C) with a maximum fluctuation of 5°F (2.8°C) per hour. The system requires two hours to warm up from a cold start to the operating temperature.
• Relative Humidity: Maintain between 20 and 80%
• Average Thermal Output: 4778 Btu/hr. for each instrument
• Average Noise Output: <70 dBA at 1 m while operating
Water Requirements:
Water Consumption: 0.85 gal. /hr. (3.2 L/hr.) maximum throughput
• Deionized water NCCLS Type 2.
• System is supplied with water system.
• Water must have from 5–7 ppm dissolved air.
Waste Requirements:
Liquid Waste Output: 0.85 gal. /hr. (3.2 L/hr.) maximum throughput A 11.5-ft (3.5-m) maximum discharge height (3 – 4-ft typical [1 – 1.9-m]) A 50-ft (15.2-m) tubing is supplied for external waste disposal. Maintenance of the waste tubing from the instrument to the disposal point is the responsibility of the user. The disposal point should be selected in accordance with local hazardous waste guidelines.
Electrical Installation Requirements:
Power Requirements:
• Line Voltage:
Each instrument uses a single cord. 115 VAC ± 10 V, 60 Hz, single phase, 20-amp service is required for each instrument.
• Circuit:
The instrument should have a separate, dedicated line with Hot, Neutral, and Isolated Ground in its own conduit. The conduit should start at the distribution panel and be continuous to the receptacle. Three-wire distribution to the receptacle is required for each instrument. The third (green) ground wire should start at the distribution panel and be continuous to the receptacle in accordance with NEC paragraph 250-74, exception 4, unless local codes prohibit. The ground wire should not be tied to grounds from other loads.
• Wire Size:
10 AWG wire is required to minimize the voltage drop between the distribution panel and the receptacle when each instrument operates at full current load.
• Receptacle:
The site must provide a Hubbell receptacle No. IG-8310 for installation by the hospital electrician before the instrument arrives. The receptacle must be accessible to the 9-ft (2.7-m) power cord furnished with the instrument.
• Electromagnetic Radiation:
Do not locate the instrument within 50 ft. (15 m) in any direction of an electromagnetic radiation source such as diathermy apparatus.
Operating Power (115 VAC):
• Nominal current during operation— 11 A
• Maximum power—1500 W
Leakage Current (mA for 115 VAC/60 Hz):
• Normal Supply Connections—Under 25
• Ground Disconnected—32
• Neutral Disconnected—Under 25
• Transient Overvoltage—Installation category II (branch circuit)
This complies with the requirement of UL 3101-1, CSA C22.2 No. 1010.1, and TUVPS Certification for EN 61010-1 compliance standards for nonpatient-vicinity laboratory equipment.
Phone Line Requirements: A dedicated phone line connected to the
Dimension ARx is required for installation.
• Dedicated, direct line—only the Dimension ARx is connected (not connected through a switchboard)
• Full duplex—capable of two-way transmission
• Standard phone connection (not new digital)—RJ11C or RJ11W phone jack
Host Interfacing: A 25-pin female connector is required for hookup to the male connector used for host communications port.
Installation: The Dimension ARx clinical chemistry system will be installed by a qualified Dade Behring representative. The installation will include checkout of all aspects necessary to ensure the equipment is fully operational.
The Siemens Dade Dimension ARx Test Menu
General Chemistry
• Albumin
• Calcium
• Creatinine
• Creatinine Enzymatic3
• Direct Bilirubin
• Iron
• Magnesium
• Phosphorus
• Total Bilirubin
• Total Iron-Binding Capacity2
• Total Protein
• Urea Nitrogen
• Uric Acid
Electrolytes
• Enzymatic Carbon Dioxide (CO2)
• Chloride
• Potassium
• Sodium
Enzymes
• Acid Phosphatase
• Alanine Aminotransferase
• Aldolase1
• Alkaline Phosphatase
• Amylase
• Aspartate Aminotransferase
• Creatine Kinase
• Creatine Kinase MB Isoenzyme
• Dibucaine Number1
• γ Glutamyl Transferase
• Lactic Dehydrogenase
• Lipase
• Pancreatic Amylase1
• Pseudocholinesterase
Diabetes Management
• Hemoglobin A1c2
• Glucose
• Glucose from Hemolysate
• Microalbumin
Cardiac Event
• Cardiac Troponin I
• Mass CK-MB
• Myoglobin
• NT-proBNP
Cardiac Risk Assessment
• Apolipoprotein A11
• Apolipoprotein B1
• CardioPhase hsCRP
• Cholesterol
• High Density Lipoprotein Cholesterol
• Low Density Lipoprotein Cholesterol
• Lp(a)1
• Myeloperoxidase
• Triglycerides
Thyroid
• Thyroid Stimulating Hormone
• Thyronine Uptake
• Total T3
• Total T4
• Free T4
Drugs-of-Abuse
• Urine Amphetamine Screen
• Urine Barbiturates Screen
• Urine Benzodiazepines Screen
• Urine Cannabinoids Screen
• Urine Cocaine
• Metabolite Screen
• Urine Ecstasy
• Urine Methadone Screen
• Urine Methaqualone Screen4
• Urine Opiates Screen
• Urine Phencyclidine
• Urine Propoxyphene Screen4
Toxicology
• Acetaminophen
• Ethyl Alcohol
• Salicylate
• Serum Barbiturates4
• Serum Benzodiazepines4
• Serum Tricyclic Antidepressants4
Antimicrobials
• Gentamicin
• Tobramycin
• Vancomycin
Antiarrythmics
• Digoxin
• Digitoxin
• N-Acetylprocainamide (NAPA)
• Lidocaine
• Procainamide
Therapeutic Drug Monitoring
• Carbamazepine
• Lithium
• Phenobarbital
• Phenytoin
• Theophylline
• Valproic Acid
Immunosuppressive Drug Monitoring
• Cyclosporine (CsA CO) 2
• Cyclosporine Extended Range
• (CsA C2)2
• Mycophenolic Acid (MPAT)
• Tacrolimus2
• Sirolimus2
Specific Proteins
• α1-Acid Glycoprotein
• (Orosomucoid) 1
• Antistreptolysin1
• C3 Complement
• C4 Complement
• C-Reactive Protein
• C-Reactive Protein
• Extended Range
• Haptoglobin1
• Immunoglobulin A5
• Immunoglobulin G5
• Immunoglobulin M5
• Rheumatoid Factor1
• Transferrin
Specialty
• Ammonia
• Urine/Cerebrospinal Fluid Protein
• Lactic Acid
• Prealbumin
• Human Chorionic Gonadotropin
• Hormone
• Ferritin
Prostate Cancer
• Total PSA
• Free PSA