  • MPN: Cobas 6000 + C501
MPN: Cobas 6000 + C501
Roche Cobas 6000 integrated with C501 Module



Includes:

Roche Cobas 6000 Core Unit

Roche C501 Chemistry analyzer

Cobas Link

Computer set up with latest software

Computer cart with Printer, monitor and all connections*



* This units list price is for a refurbished unit, if you would like this unit in as is working conditions please send us an offer for $14,900.00 (This Price does not include shipping.) Crating is $750, shipping is also an additional $750, $1500 total flat rate shipping.

Features:

CORE UNIT :

l Simple operation with continuous loading and unloading

l Loading capacity of 150 samples in two trays of 75

l Load 5-position racks via dedicated STAT port with rerun buffer or by tray

l Unique 5-position rack for more efficient sample handling

l Smart track rotor for intelligent sample handling

l Single control unit for all modules

COBAS C501 MODULE

l Clinical chemistry, homogeneous immunoassays, ISE, HbA1c (whole blood measurement).

l Throughput of up to 1,000 tests/hour

l 60 reagent channels plus 3 ISE's

l Reagent loading on the fly

l Specimen integrity via serum indices (parallel processing), clot and liquid level detection

l Contact-free ultrasonic mixing

l Automated rerun and dilution

Specifications:

System:

2nd Generation SWA: modular, analytical system platform, consolidated work area for Clinical Chemistry and Immunology, expandable and re-configurable on site

Types of modules

cobas c 501 module: Photometric measuring unit (incl. ISE)

Number of configurations

5 module combinations; Up to 3 modules in one core unit

cobas c 501 modules: 1 to 2 modules

Test throughput (theoretical max)

170 up to 2,170 tests/hour: overall

1,000 up to 2,000 tests/hour: with cobas c 501 modules

Number of reagent channels

(reagent slots)

Up to 151 channels, in total 63 channels (including ISE, automatic setting) on cobas c 501 module



Sample material

Serum, Plasma, Urine, CSF

Core unit analytics

Rack: 5 position rack, RD standard rack

Rack types: Routine, STAT, Control, Calibrator, Rerun (manual), Wash

Tray: Tray with 15 racks/75 samples, RD standard tray

STAT port: STAT samples are processed with true STAT interrupt

Sample container types

Primary tubes: 5 to 10 mL; 16 x 100, 16 x 75, 13 x 100, 13 x 75 mm

Sample cup: 2.5 mL

Micro cup: 1.5 mL

Cups on tube: Cup on top of a 16 x 75/100 mm tube; Cup on top of one non standard tube

False bottom tube (FBT): One type is definable

Sample volume 135 L

Sample dilution 3121 times

Sample clot detection

Available for cobas c 501

Minimum sample volume

Primary tubes: 700 L

Sample cup: 100 L

Micro cup (FTB): 50 L

Sample barcode types

Code 128; Codabar (NW 7); Interleaved 2 of 5; Code 39

System interfaces

RS 232 serial interface, bi-directional Interface to cobas link data station for cobas teleservice functionalities and automatic download

Sample data base

10.000 routine/STAT samples

Test methods

For photometric modules: 1 point, 1 point + prozone check, 2 point, 2 point kinetic, 2 point + prozone check, 3 point, 1 point + kinetics Rate A, Rate A + serum index, Rate A with blank, Rate B

Calibrator/QC input

Via specified racks through the input buffer or STAT port

Calibration methods

Start-up, Re-calibration For photometric modules: Linear, non-linear multi-points, 2 point calibration, K-factor up to 100 different calibrators pre-programmable Storage of up to 180 curves Preventive calibration of the stand-by cobas c and cobas e packs on cobas c 501: Two k-factor can be defined for different sample types

QC methods

For e- and photometric modules: Real-time QC, individual QC, cumulative QC Up to 100 controls pre-programmable Preventive QC after calibration of the stand-by cassettes/rack packs Auto QC: QC without operator intervention (timer triggered)

Rerun/reflex function

Automatic rerun and manual rerun; Automatic reflex is supported by the system, reflex request to be provided by Roche Middleware Solutions

Electrical requirements

Power requirements: 230 Volts AC; 110 Volts AC 2.4 kVA (for cobas c 501)

Frequency: 50 Hz or 60 Hz +/- 0.5%

Water/waste requirements

Water: Bacteria free, deionised water supply: resistance of < 1,0 S/cm

Water pressure: 0.5 3.5 kg/cm3, (49343 Kpa)

Biohazards waste: Separate container behind the system

L. concentrated: Central drain port, diameter: = 50 mm / 2 inches

Waste drain < waste: 100 mm above the floor / 4 inches

Water consumption

Max flow rate: cobas c 501 module: approx. 40 L/hour

Operational conditions

Ambient temperature: 15 to 32C / 59 to 90F

Ambient humidity: 30 to 85% (RH, without condensation)

Heat output: 1.5 kW (5400 kJ/hr for cobas c 501, 4320 kJ/hr for cobas e 601)

Noise output: < 65 dB

Physical dimensions

Width: 188 to 498 cm / 74 to 196 inches

Core unit: 69 cm / 27.2 inches cobas c module: 120 cm / 47.2 inches

Depth: cobas c module: 98 cm / 38.6 inches Core unit: 104 cm / 41 inches

Height: 130 cm / 51 inches

Weight

cobas c 501 module: 330 kg / 730 lbs

Core unit (sample loader, control unit, rack rotor): 180 kg / 400 lbs

Refurbishment Protocol:

Our technicians decontaminate and clean equipment upon arrival at our facility and upon your purchase to create a neutral environment for your lab use.

Preliminary testing is then conducted on our equipment to identify potential defects. Upon completion, we replace all faulty and/or under-performing parts with original manufacturer parts that perform up to specification.

Any parts known to fail or malfunction on the piece of equipment are removed and replaced to insure the extended lifetime of your equipment.

Any necessary preventative maintenance is performed alongside repairs, so your purchase will be ready to go as soon as it arrives.

All of the electronics and boards are tested for proper function and response by our industry trained technicians. Any electronic deficiencies detected are immediately repaired.

Final testing cycles ensure your equipment performs fully at manufacturer specifications, guaranteeing you receive a properly working product ready for use.

Once we finish our rigorous testing and decontamination procedures, your order will be packaged to best protect it during shipment and may include delivery insurance depending on value.

* Free 30 day Returns

* Free Same Business Day Shipping

* Top Rated Plus Product

* This product is available also in different quantities and cases please ask us for details

- Call or email with your questions , Hablamos Espaol

- Ship from: Southern California. Global Shipping

- Details of item must be read carefully before buying and /or requesting return

Disclaimer:

"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not buy this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
International Diagnostic Equipment
profile image
Shop with confidence
Citi Capital Groupspacer
Moveitem Shippingspacer
Send the Seller a message: