Ken Sourounis, Managing Partner
DOTmed user since April 2014
Installed on Philips 4k magnets, this compressor operates a the RDK-408C2, RDK415C2, RDK408-C3, and RDK-415C3 Coldheads. Sumitomo RDK-408A2 Sumitomo RDK-408 Sumitomo RDK408T Sumitomo RDK-400 ... view more
480v 5.6kW Helium compressor. These are available on exchange. Service Life ... view more
Available as an upgrade to the RW4000 compressor. It offers increased reliability and increased capacity. Sumitomo RDK-408A2 Sumitomo RDK-408 Sumitomo RDK408T Sumitomo RDK-400 Sumitomo RDK-408C2... view more
The Sumitomo CNA-61 is a split system compressor. It allows the heat exchanger to be installed remotely to help manage heat build-up in the equipment... view more
An air cooled helium compressor designed to run with RDK-205D and RDK-205N coldheads. These are available on exchange. Service Life ... view more
Leybold RW-3 Compressor. This is a single phase compressor that can opperate between... view more
Leybold Coolpak6000H desigend to run Leybold coldheads and cryopumps. These are available on exchange. Service Life ... view more
Leybold Coolpak6000H desigend to run Leybold coldheads and cryopumps. These are available on exchange. Service Life ... view more
The CoolPak4000 Compressor is an excellent choice to upgrade an RW4000 compressor. The CoolPak Adsorber should be replaced every 18,000 hours and with each coldhead service to help avoid system... view more
Installed in G.E. S-Series magnets, the Balzers compressors drive the 325-ST, 328-ST, and 065 Balzers coldheads. The Balzers Adsorber should be replaced every 2 years and with each coldhead service... view more
Installed on Philips T5, NT, and F2000 magnets, this compressor drives the APD SC-8, APD SC-8C, and APD SC-8R Coldheads. The HC-8E Adsorber should be replaced every 3 years and with each coldhead... view more
Helium compressor for Toshiba MRI. These are available on exchange. Service Life ... view more
The RDK-415D3 is the 3rd Generation of the Sumitomo 4 Kelvin Coldhead with 1.5 Watt Second Stage capacity. The CSW adsorber should be replaced every 20,000 hours (28 months) and with each coldhead... view more
Installed in Philips zero boil-off magnets, the RDK-415C3 coldhead is operated by the CSW-71D Compressor. The CSW adsorber should be replaced every 20,000 hours (28 months) and with each coldhead... view more
Installed on G.E. S-Series and CX magnets, this coldhead can be operated by Sumitomo CSW-71D, CSW-71C, CSA-71A, and F-50 compressors. It can be isntalled as an upgrade to Balzers and Leybold... view more