Over 850 Total Lots Up For Auction at One Location - NJ Cleansweep 06/13

ORTHO-CLINICAL DIAGNOSTICS DT 60 Chemistry Analyzer

(1)
Information Provided By:
Get all the benefits of VITROS® MicroSlide™ Technology in a size that's perfect for your laboratory. Fast, more accurate results with an easy-to-use, cost-effective solution. The modular VITROS® DT60 II Chemistry System suits your workflow perfectly.
Scalable solutions enhance your laboratory's performance
You'll get the ultimate in flexibility and value with this modular chemistry system. Extensive test menu covers a full range of assays and applications, including basic chemistries, electrolytes, enzymes, full lipid profiles, and derived tests.
Provides the convenience and reliability for routine or emergency clinical chemistry testing in many facilities including:
• Physician offices - individual and group practices
• Clinics - outpatient, multi-specialty, hospital-affiliated and independent
• Hospitals - central lab, emergency department, surgical units, intensive care / coronary care units, geriatric / pediatric / neonatal units, dialysis centers
• Commercial labs - drawing stations, satellite labs
MicroSlide Technology: Small and powerful
MicroSlide Technology is designed to provide the highest reagent efficiency in the industry. Overall costs will be more predictable, and you'll get greater value for your investment.
The MicroSlide's thin layer of microfilm have all the reagents you need to test and filter out interfering substances - functions that are normally associated with larger, more expensive systems, not one designed for the benchtop.
Three Simple Steps
1.) Prepare sample
Draw the sample via fingerstick or venipuncture. Centrifuge for as little as 30 seconds.
2.) Spot slides
Approximately 10 microliters of plasma or serum are required for each test.
3.) Read results
Printed in just two to five minutes. A hard-copy printout of the test results and patient ID eliminates transcription errors.
VALUE. VARIETY. VERSATILITY. VITROS
You'll enjoy:
Advanced Security
Dry slides filter interferences, generating accurate, worry-free results. Additionally, by using direct ISE slides, you can be confident that there's virtually no chance of pseudohyponatremia or any maintenance of electrodes.
Labor Optimization
Free your staff for more value-added tasks with a system that's simple to use and requires no reagent mixing, minimal maintenance, and calibration only when you change reagent lots.
Enhanced Service Levels Get consistently accurate results in two to five minutes. Random access testing lets you run chemistries in any order you choose. The small sample size is especially helpful for pediatric, geriatric, and hard-to-test patients. With all three modules, you can run up to 100 tests per hour.
Cost Containment Save time and make more efficient use of consumables. There's minimal waste, no plumbing, and nominal storage requirements.
Specifications
DT60 II Analyzer :
Width: 47.6 cm (18.75 in) Depth: 34.9 cm (13.75 in) Height: 17.1 cm (6.75 in) Weight: approximately 8.6 kg (19 lbs.)
DTSC II Module :
Width: 34.3 cm (13.5 in) Depth: 35.4 cm (13.9 in) Height: 16.5 cm (6.5 in) Weight: 7.7 kg (17 lbs.)
DTE II Module :
Width: 14.6 cm (5.75 in) Depth: 35.4 cm (13.9 in) Height: 16.5 cm (6.5 in) Weight: approximately 2.7 kg (6 lbs.)
Voltage for all components:
110-240 VAC (50-60 Hz) RS-232 port for computer interface
VITROS® DT60 II Test Menu:
Ammonia Amylase Cholesterol BUN/UREA Glucose HDL Cholesterol Lactate
Magnesium Neonatal Bilirubin Phosphorous Total Bilirubin Total Protein Triglycerides Uric Acid
VITROS® DTSC II Test Menu:
Albumin Alkaline Phosphatase ALT AST Calcium Cholinesterase CK CKMB
Creatinine GGT Iron LDH Lipase Lithium Urine Creatinine
VITROS® DTE II Test Menu:
Carbon Dioxide Sodium
Chloride Potassium
Derived Tests:
A/G Ratio Anion Gap Coronary Risk Classification Cholesterol/HDLC Ratio
Globulin LDL VLDL
See a missing Specification? Want to make a correction? Add it now
Weight:
8.6 kg (19 lbs.)

Share your opinion or experience with this equipment Review this model

(11)
(2)
(12)
(18)

Jason Fisher

Ergonomics

March 15, 2014 12:07

starstarstarstarstar

Easy to use.

Log inor Register

to rate and post a comment