New MRI Standards Announced by NEMA

by Joan Trombetti, Writer | November 06, 2008
NEMA
The National Electrical Manufacturers Association (NEMA) has published three standards for magnetic resonance imaging (MRI) systems. The standards that pertain to signal-to-noise ratios, specific absorption rates, and signal intensity in images acquired with phased array coils were produced by the Medical Imaging & Technology Alliance, a division of NEMA.

Specifically, MS 6-2008 Determination of Signal-to-Noise Ratio and Image Uniformity for Single-Channel Non-Volume Coils in Diagnostic MRI lists a method for evaluating single-channel non-volume special purpose radio-frequency coils used with MRIs. Excluded are system head and body coils, single-channel volume specialty coils, and coils that require multiple receiver channels for operation.

MS 8-2008 Characterization of the Specific Absorption Rate for MRI Systems defines calorimetric and pulse-energy methods for determining SARs in either a phantom or a patient. Results from either method may then be extrapolated to other scan parameters and even to other waveforms.
stats
DOTmed text ad

We repair MRI Coils, RF amplifiers, Gradient Amplifiers and Injectors.

MIT labs, experts in Multi-Vendor component level repair of: MRI Coils, RF amplifiers, Gradient Amplifiers Contrast Media Injectors. System repairs, sub-assembly repairs, component level repairs, refurbish/calibrate. info@mitlabsusa.com/+1 (305) 470-8013

stats
MS 9-2008 Characterization of Phased Array Coils for Diagnostic MRIs describes a standard way for measuring and reporting SNR and uniformity of signal intensity in images acquired with phased array coils. According to NEMA, these quantities are useful in evaluating the impact of system changes on performance or in demonstrating effectiveness for Federal Drug Administration applications.

Manufacturers can use these standards when determining system performance specifications. Furthermore, NEMA said, "The standardization of performance specifications benefits the prospective equipment purchaser, and the parameters supplied with each NEMA measurement serve as a guide to those factors that can influence the measurement." Standards also can serve as reference procedures for acceptance testing and periodic quality assurance.

Download the standards at no charge from NEMA:
http://www.nema.org/media/pr/20081027b.cfm

For an industry sector report on MRI coils, read the November issue of DOTmed Business News, now online.