Over 950 Cleansweep Auctions End Tomorrow 05/02 - Bid Now
Over 800 Total Lots Up For Auction at Four Locations - TX 05/03, TX 05/06, NJ 05/08, WA 05/09

spacer
Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313
Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313 Listing 4836313

For Sale PHILIPS BrightView XCT SPECT/CT

  • Condition : Used - Good
  • Qty. Available : 1
  • In Stock : Yes
  • Date : April 27, 2024
  • Listing # : 4836313
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4836313

  • Condition: Used - Good
  • Brand: PHILIPS
  • Type: SPECT/CT
  • Model: BrightView XCT
ENM00025 - Philips SPECT/CT Brightview XCT
System YOM: 2013
Modality: NM
Manufacturer: Philips
Model: Brightview XCT
System functional: Yes
Is the system used only in human environment? Yes - Has been used ONLY on Humans
Serviced by: Original manufacturer.
List and description of collimators (HiRes, Div/Con, LEAP, Pinhole...): LEHR, MEGP, HEGP, HEPH
Is it a single or a double head? Double
If SPECT capable, add the number of slices: 64
Crystal thickness: 3/8''
Crystal condition: ok
Detector: Countervalue
Comments: Wall-mount acquisition, Dual control room monitor and in-room control, BV XCT Premium comfort kit, Ivy Gate, Ivy Gate rolling cart, oncology underpad, adjustable knee wedge, carbon fiber pediatric paddle, headrest and pads for Brain, floor table kit
QA Report has been attached to this document.
SYSTEM LOCATION Hospital Neuchâtelois, La Chaux-De-Fonds - Switzerland
PROJECT NO. 11755284424
PERFORMED BY Samir AHMED
DATE December 18th 2023
SYSTEM INFORMATION

Manufacturer and model PHILIPS Brightview XCT
System ID /
System YOM 03-2013
Number of slices Not available
Cooling Air cooling
Gantry YOM 03-2013
Gantry model no. 453560462131
Gantry serial no. 6000379
PDU INFORMATION (TRANSFORMER INFO)

PDU/transformer model no. INDICO 100RF 40KW
PDU/transformer serial no. AM17179A13
PDU/transformer YOM 01-2013
CONSOLE AND WORKSTATION(S) INFORMATION

Console Inside the gantry
ACCESSORIES, MANUAL HARD-COPIES AND SOFTWARE DISCS

Software (Present Yes/No)
YES
Back-up (Present Yes/No) YES
Manuals (Present Yes/No) YES
Any additional items/accessories? ECG Monitor
Transport Brackets (Present Yes/No) YES
COMMENTS
Functional condition Very good
Cosmetic condition Good
Parts missing towards CL No

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Technomed Medical Parts & Equipment
profile image
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: