The Features:
1. Designed to fully comply with IEC60601
2. Controlled by Dual-CPU
3. Automatically self-defined size of syringe: 5ml, 10ml, 20ml, 30ml, 50/60ml.
4. Drug-weight mode, programming function and Bolus mode available
5. Drug Library: Build-in 48 drugs and could expand to thousands
6. Event Record function
7. Anti-Bolus function
8. Occlusion pre-alarm
9. Key lock function
10. Preset 8 syringe brands, new brand can be user-defined.
11. Piggyback function is available
12. Pressure auto release function when occlusion occurs, reducing potential risk.
Syringe Size: 5ml,10ml,20ml,30ml,50ml
Injection Mode
Normal mode, Time Mode, Programming Mode, Weight mode and
Drug Library Mode
Accuracy Error Rate ±2% (mechanical precision ±1%), < 1ml/h ±5%
Flow Rate Range
5ml syringe: 0.1~150.0ml/h
10ml syringe: 0.1~300.0ml/h
20ml syringe: 0.1~400.0ml/h
30ml syringe: 0.1~600.0ml/h
50ml/60ml syringe: 0.1~1200.0ml/h (step 0.1ml/h)
VTBI 0.1-9999.9ml (step0.1ml)
Total Volume Range 0-9999.9ml (step 0.1ml)
KVO 0.1-20.0ml/h ; Default:1ml/h
Purge
5ml syringe: 150.0ml/h
10ml syringe: 300.0ml/h
20ml syringe: 400.0ml/h
30ml syringe: 600.0ml/h 50ml/60ml syringe: 1200.0ml/h
BOLUS
1. Rate & Volume could programming while pumps working;
(Default: 600ml/h ,VTBI:2ml)
2. Bolus rate is followed the last setup with no limited of VTBI.
(Default: 600ml/h)
Occlusion Pressure
High: (80±10) kPa
Mid : (60±10) kPa
Low: (45±10) kPa
Occlusion pre-alarm
When monitoring the pressure on the high side, Occlusion
pre-alarm
Alarm
Near empty of syringe, under-voltage battery, power interruption,
wrong installation of push-handle clip, wrong installation of
compressive bar, wrong installation of pushing bar, end of infusion,
suspension time-out, pushing of empty syringe, abnormal power
supply, system mistake, internal communication mistake,
abnormal speed, occlusion pre-alarm syringe occlusion alarm,
battery running-out, battery damage
CPU Dual-CPU
Lock Key Key Locking to avoid carelessness the parameter
Fast Start Overcome dose delay
Anti-Bolus Back off system to reduce pressure and quick release of occlusion
Drug Library
Build-in 48 drugs and could expand to thousands if customer
needed.
Piggyback Do not need stop the pump to change the parameters directly.
Programmable Maximum 8 integrates infusion
History Records
1500 event records, 200 modified records,Historical record can be
check in the machine directly
Records can be exported in LAN.
Power Supply AC100V~240V,50Hz/60Hz ,15VA
Battery
Ni-MH battery, DC9.6V, 2000mAh; fully-charged battery can be
used for over 7 hours at a speed of 5ml/h;
Display Industrial-grade true color display
Installation Desktop, transverse, longitudinal
Electrical Safety Classification Class I with inner power, IPX4, CF
Dimension 140mm×145mm×325mm(D x H x L)
Net Weight 1.9Kg
Operation Condition
Temperature: 5°C ~ 40°C;Relative humidity: 20% ~ 90%
Atmospheric pressure: 70 ~ 106kPa
Application Applicable for intravenous injection
Return Policy
Items are sold as-is with no returns or refunds available unless explicitly stated.
Tags:
IV Infusion Pump