Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094
Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094 Listing 4880094

For Sale BUNNELL High Frequency Infant Ventilator Life Pulse 203A w/ Patient Box

  • Asking Price :$2,799.00 USD [convert]
  • Condition : Used - Good
  • Est. Shipping : Calculate
  • Weight : 60.00 Lbs
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 26, 2024
  • Listing # : 4880094
  • credit-card
  • credit-card
  • credit-card
  • credit-card
cps-logo Get a CPS 2-Year Protection Plan starting at $5.99. Sold separately. Learn more
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4880094

  • Condition: Used - Good
  • Brand: BUNNELL
  • Type: Other
  • Model: High Frequency Infant Ventilator
  • MPN: 203A
  • Depth: 20 inches
  • Height: 20 inches
  • Width: 20 inches
MPN: 203A
br vocab="" typeof="Product"> ~ ~ : This Bunnell Life Pulse 203 Infant High Frequency Jet Ventilator is in excellent cosmetic and power tested working condition. This units shows very little signs of wear from previous use with no visible damage. All of the LED displays, audible and visual alarms and indicator lights are working and I am able to adjust values using the buttons. The Humidifier unit on front of the device is intact and in excellent condition. The Patient Box is in excellent undamaged condition as well. Age unknown but I see this model is still being advertised on the Bunnell website so I assume it is still supported.The Life Pulse unit is a system that offers a variety of options for managing patients and the potential for improving blood gases using less pressure. This microprocessor-controlled infant ventilator is capable of delivering and monitoring between 240 and 660 heated, humidified breaths per minute. Guaranteed not to be DOA!

Bunnell Life Pulse 203A High Frequency Infant Ventilator w/ Patient Box

Bunnell Life Pulse 203A High Frequency Infant Ventilator w/ Patient Box

Click images to enlarge



Description

~ ~:



This Bunnell Life Pulse 203A Infant High Frequency Jet Ventilator is in excellent cosmetic and power tested working condition. This units shows very little signs of wear from previous use with no visible damage. All of the LED displays, audible and visual alarms and indicator lights are working and I am able to adjust values using the buttons. The Humidifier unit on front of the device is intact and in excellent condition. The Patient Box is in excellent undamaged condition as well. Age unknown but I see this model is still being advertised on the Bunnell website so I assume it is still supported. I have the original cart if you need it for an additional cost.

The Life Pulse unit is a system that offers a variety of options for managing patients and the potential for improving blood gases using less pressure. This microprocessor-controlled infant ventilator is capable of delivering and monitoring humidified breaths per minute.Guaranteed not to be DOA!

Specifics



Bunnell Life Pulse Infant Ventilator

Model: 203A
Serial No: 2491
Hours: 21291.1
Airway Pressure Sensitivity: 0.1cm H2O
Airway Pressure Accuracy: 0.5cm H2O
Servo Pressure Sensitivity: 0.04psi (0.276kPa)
Servo Pressure Accuracy: 1.0psi (6.895 kPa)
HFV/PB Airway Pressure Accuracy: 1.5cm H2O
Gas Supply Requirements: 30 to 60psi (206.85 - 413.7 kPa)
Power: 120VAC , 60Hz , 1.1Amps
6ft Power Cord
Patient Box- (s/n: 4842)

Condition

This device is in excellent cosmetic and power tested working condition. The unit powers on and all of the digital read outs are working. All visual and audible alarms are functioning. Allsoft touch buttons and gas ports are intact and working. I am easily able to adjust display values using the buttons. The Patient Box and the Humidifier are bothpresent and in excellentcondition. Total hours of use meter on this device reads 21291.1 total hours. No further testing is possible but I believe it is working.

Manufacturer's Description



The Bunnell Life Pulse High-Frequency Ventilator is indicated for use in ventilating critically ill infants with pulmonary interstitial emphysema (PIE). Infants studied ranged in birth weight from 750 to 3529 grams and in gestation age from 24 to 41 weeks. The Bunnell Life Pulse High-Frequency Ventilator is also indicated for use in ventilating critically ill infants with respiratory distress syndrome (RDS) complicated by pulmonary air leaks who are, in the opinion of their physicians, failing on conventional ventilation. Infants of this description studied ranged in birth weight from 600 to 3660 grams and in gestational age from 24 to 38 weeks.

Age

Unknown

Dimensions

Ventilator: 14.5" wide x 19 " long x 14 " tall
Patient Box: 7" wide x 6" long x 4" tall
Power Cord: 8'

Warranty

I stand behind everything I sell and for 30 days I guarantee thisBunnell Life Pulse 203A High Frequency Infant Jet Ventilatoris exact to the description and pictures I have provided here or return it for a refund

Shipping

Weight before packing is44lbsfor everything pictured.
All buyers may use the shipping calculator.
Pickup is always welcome from our warehouse in Coolidge Az (40 miles south of Phoenix Az near I-10).
If the shipping calculator wont give you a shipping cost you must contact me for a shipping quote.

_______________________________________________________________

"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not buy this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item."

Regardless of the origin of the equipment, documentation provided or identification appearing upon the equipment, the equipment described and offered here is in no way certified for, recommended for, or offered for any specific use. The purchaser agrees that the seller shall not be held responsible or liable for any injuries or damages, whether incidental or consequential, associated in any way with the equipment.. The purchaser, indicates their acknowledgment of, and agreement to the terms of this disclaimer. There are no warranties which extend beyond the description on the face hereof. This item has been cleaned and handled in accordance with the manufacturer's instructions..

,
















Return Policy

Seller Information
Budget Medical
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: