Complete ST Jude Medical

EnSite™ Amplifier
The EnSite™ Amplifier subsystem consists of the EnSite™ Amplifier, NavLink™ Module, ArrayLink™ Module, CathLink™
Module, SJM ECG Cable, RecordConnect, and GenConnect. The devices accept signals from electrodes attached to the patient and
pass these signals to the EnSite™ Amplifier. The EnSite™ Amplifier converts these signals to a digital format and sends them to the
DWS for processing.
EnSite™ Amplifier. Accepts signals from the NavLink™ Module, the ArrayLink™ Module, the CathLink™ Module, SJM ECG
Cable, RecordConnect, and GenConnect, converts these signals to a digital format, and sends them to the DWS for processing. The
Amplifier is connected to the DWS through a fiber-optic cable.
NavLink™ Module. Connects the EnSite™ surface electrodes and the system reference surface electrode to the Amplifier. It also has
a connection for an auxiliary unipolar reference electrode.
ArrayLink™ Module. Connects the EnSite™ Array™ catheter to the EnSite™ Amplifier.
CathLink™ Module. Connects diagnostic catheters to the EnSite™ Amplifier.
SJM ECG cable. Connects standard ECG electrodes to the EnSite™ Amplifier.
RecordConnect. Connects a recording system to the EnSite™ Amplifier without the need for jumpers. A different RecordConnect
model is required for each make of recording system.
GenConnect. Connects the ablation catheter and dispersive surface electrodes to the EnSite™ Amplifier. It isolates the EnSite™
Velocity™ Cardiac Mapping System location signal from being loaded by the ablation generator, thereby eliminating the need for
separate dispersive electrode filters. A different GenConnect model is required for each make of ablation generator.
NOTE: GenConnect is not necessary when using the Ampere™ Generator.
Display Workstation (DWS)
The DWS consists of the workstation (computer), monitors, medical grade isolation transformer, video extender, media converter, and
Ethernet switch.
Workstation. The workstation contains the system software displaying data from the EnSite™ Amplifier. Attached to the workstation
are a keyboard and mouse for user input.
Monitors. Monitors are used to display patient information. One monitor is placed near the workstation and keyboard for system
operation,
Medical Grade Isolation Transformer. All system components on the DWS cart are connected to line power through the isolation
transformer. Only components of the DWS should be connected to this isolation transformer.
Media Converter. The Media Converter converts optical signals to digital signals. It connects to the hardware via a Fiber Optic Cable
and connects to the DWS via an Ethernet cable and a USB cable, which is used for power only.