Over 100 Total Lots Up For Auction at One Location - CA 05/31

spacer
Listing 4887239 Listing 4887239 Listing 4887239
Listing 4887239 Listing 4887239 Listing 4887239

For Sale ABBOTT EnSite Precision Cardiac Mapping System EP Lab/X-Ray Room

  • Condition : Used - Good
  • Qty. Available : 1
  • In Stock : Yes
  • Date : April 21, 2024
  • Listing # : 4887239
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #4887239

  • Condition: Used - Good
  • Brand: ABBOTT
  • Type: EP Lab/X-Ray Room
  • Model: EnSite Precision Cardiac Mapping System
Abbott/St Jude EnSite Precision Cardiac Mapping System
Compatible with all OEM Catheters
System Components
The EnSite Precision™ Cardiac Mapping System is comprised of two subsystems: the EnSite™
Amplifier and the Display Workstation (DWS).
EnSite™ Amplifier
The EnSite™ Amplifier subsystem consists of the EnSite™ Amplifier, NavLink™ Module,
ArrayLink™ Module, CathLink™ Module, SJM™ ECG Cable, RecordConnect, and GenConnect.
The devices accept signals from electrodes attached to the patient and pass these signals to the
EnSite™ Amplifier. The EnSite™ Amplifier converts these signals to a digital format and sends
them to the DWS for processing.
EnSite™ Amplifier. Accepts signals from the NavLink™ Module, the ArrayLink™ Module, the
CathLink™ Module, SJM™ ECG Cable, RecordConnect, and GenConnect, converts these signals
to a digital format, and sends them to the DWS for processing. The Amplifier is connected to
the DWS through a fiber-optic cable.
EnSite Precision™ Module, Sensor Enabled™. Consists of the EnSite Precision™ Link, Sensor
Enabled™, the EnSite Precision™ Field Frame, and two (2) Patient Reference Sensors.
NavLink™ Module. Connects the EnSite™ surface electrodes and the system reference surface
electrode to the EnSite™ Amplifier. It also has a connection for an auxiliary unipolar reference
electrode.
ArrayLink™ Module. Connects the EnSite™ Array™ catheter to the EnSite™ Amplifier.
CathLink™ Module. Connects diagnostic catheters to the EnSite™ Amplifier.
SJM™ ECG cable. Connects standard ECG electrodes to the EnSite™ Amplifier.
RecordConnect. Connects a recording system to the EnSite™ Amplifier without the need for
jumpers. A different RecordConnect model is required for each make of recording system.
GenConnect. Connects the ablation catheter and dispersive surface electrodes to the EnSite™
Amplifier. It isolates the EnSite Precision™ Cardiac Mapping System location signal from being
loaded by the ablation generator, thereby eliminating the need for separate dispersive
electrode filters. A different GenConnect model is required for each make of ablation
generator.NOTE: GenConnect is not necessary when using the Ampere™ Generator.

Display Workstation (DWS)
The DWS consists of the workstation (computer), monitors, medical grade isolation transformer, video extender, media converter, and Ethernet switch.
Workstation. The workstation contains the system software displaying data from the EnSite™ Amplifier. Attached to the workstation are a keyboard and mouse for user input.
Monitors. Monitors are used to display patient information. One monitor is placed near the workstation and keyboard for system
operation, and an optional second monitor can be placed near the patient table for use by the physician. The monitors display identical information from the same source.
Medical Grade Isolation Transformer. All system components on the DWS cart are connected to line power through the isolation transformer. Only components of the DWS should be connected to this isolation transformer.
Media Converter. The Media Converter converts optical signals to digital signals. It connects to the hardware via a Fiber Optic Cable
and connects to the DWS via an Ethernet cable and a USB cable, which is used for power only.
Ethernet Switch. The Ethernet Switch allows users to use multiple modules that require Ethernet connections in conjunction with the EnSite Precision™ Cardiac Mapping System.
Components Not Included
The following components are required for EP studies but are not included with the EnSite Precision™ Cardiac Mapping System.
EnSite™ Array™ Catheter. This noncontact multi-electrode catheter collects cardiac electrical information.
Conventional and Sensor Enabled™ EP Catheters . These catheters are introduced into the cardiac chamber of interest and placed in contact with the chamber wall.
Surface Electrodes – Six surface electrodes are used for the EnSite™ Cardiac Mapping System.
Patient Reference Sensor Patches – Two patches are used to place the two Patient Reference Sensors (PRS) that are used with the EnSite Precision™ Cardiac Mapping System.
ECG Electrodes. These industry-standard surface electrodes are placed in a standard 12-lead configuration.
System Reference Surface Electrode. A system reference surface electrode is required for all EnSite™ ArrayLink™ Module andEnSite™ NavX™ Navigation and Visualization Technology studies. This surface electrode should be suitable for defibrillation orelectrosurgery, such as the Covidien™ Valleylab™ Non-REM Polyhesive™ Patient Return Electrodes.

Return Policy

Items are sold as-is with no returns or refunds available unless explicitly stated.
Seller Information
Heritage Radiology, LLC
profile image
Shop with confidence
Citi Capital Groupspacer
Send the Seller a message: