Over 150 Total Lots Up For Auction at One Location - CA 05/31

spacer
Listing 3590680 Listing 3590680
Listing 3590680 Listing 3590680

For Sale POCVODA EH737 Pump IV Infusion

  • Asking Price :$225.00 USD [convert]
  • Condition : New
  • Qty. Available : 1
  • In Stock : Yes
  • Date : May 15, 2024
  • Listing # : 3590680
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #3590680

  • Condition: New
  • Brand: POCVODA
  • Type: Pump IV Infusion
  • Model: EH737
  • Warranty: 2 years
Main features
Reliable and Safe:
1, Additional set of bubble alarm design(double bubble alarm) ensure more secure infusion;
2, Advanced safety design able to stop infusion and alarm even if the CPU damage,the medical staff can ues it safely;
multipurpose:
It can be transfused, transfused blood and transported nutrient solution.

Pumping way
Semi-squeeze finger-type peristaltic pump

IV-sets
Special or quality PVC/TPE infusion sets with an external diameter of 3.4mm~4.5mm

User options: No

Infusion modes
4 infusion modes:
1, Flow-rate: ml/h;
2, Time-amount: ml/h;
3, Drop-rate: d/min;
4, Body-weight: mg/kg/h

Parameter range
1, Flow-rate: 1.0~1200.0 ml/h, 0.1ml/h step;
2, Time: 1s~99h59m59s, 1s step;
3, Drop-rate: 1~333 d/min, 1 d/min step;
4, Dose: 0.1~999.9 mg, 0.1mg step;
5, mg/kg/h: 0.001~999.999 mg/kg/h, 0.001 mg/kg/h step;
6, Body-weight: 1~300 kg, 1kg step;
7, KVO rate: 1.0~5.0 ml/h, 0.1 ml/h step;
8, Bolus rate: 50.0~800.0 ml/h, 0.1 ml/h step;
9, Bolus volume: 0.1~99.9 ml/h, 0.1ml step

Precision
Better than ±5% (using a calibrated or a special IV-set)

Alarm
1, Air in tube, 5 grades of sensitivity (double bubble alarm);
2, Bubble sensor fault;
3.1, Upper-end occlusion, -20~ -60 kPa,8 grades of sensitivity;
3.2, Upper-end base-pressure fault;
4.1, Lower-end occlusion, 20~ 140 kPa,8 grades of sensitivity;
4.2, Lower-end base-pressure fault;
5.1, Pump rotation fault;
5.2, Inverse-infusion;
6, Abnormal door-opening;
7, Low battery power, battery fault;
8, Overtime pause;
9, Completed infusion;
10, AC power fault;
11, MCU fault, and stop infusion;
12, Battery temperature is too high.

Data function
1, Memory of calibration: Records the calibration data of tube automatically for application;
2, Memory of parameter: Records the latest infusion parameter for next operation;
3, Historical records: records latest 1000 infusion events.
(what/when/why,flow-rate, etc.)

Safety classification
Class I; Internal power supply, CF type, IPX4 equipment

Power supply
AC 100~240V, 50/60Hz, Built-in rechargeable Li-battery
Power consumption:20VA
Working time of battery: 7h@25ml/h

Weight and size
130mm(w)*206mm(h)*118mm(t); about 1.6kg

Optional accessories
1, Warmer;
2, Wireless communicating module.

Return Policy